ORIGINAL ARTICLE
Year : 2020  |  Volume : 39  |  Issue : 3  |  Page : 756-763

Outcomes of balloon angioplasty for failing upper extremity dialysis access


Department of Vascular and Endovascular Surgery, Assiut University Hospitals, Assiut, Egypt

Date of Submission19-Mar-2020
Date of Decision31-Mar-2020
Date of Acceptance03-Apr-2020
Date of Web Publication28-Aug-2020

Correspondence Address:
MD Mohamed Ibrahim
Department of Vascular and Endovascular Surgery, Assiut University Hospitals, Assiut 71526
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ejs.ejs_69_20

Rights and Permissions
  Abstract 


Background Percutaneous transluminal angioplasty (PTA) is the mainstay of treatment in stenosed hemodialysis access. Being less invasive and outpatient procedure, PTA is a safe and useful intervention to maintain access patency in patients with failing hemodialysis arteriovenous fistulas (AVFs). The aim of this study was to evaluate the efficacy of balloon angioplasty in treatment of patients with failing upper extremity hemodialysis access.
Methods This is a prospective study of all adult patients who underwent balloon angioplasty for the treatment of patients with symptoms of a failing dialysis access due to presence of significant stenosis in dialysis access circuit. The study conducted at the Department of Vascular and Endovascular Surgery, Assiut University Hospital (a tertiary referral hospital), between January 2017 and December 2018. Both the primary and assisted primary patency rates were analyzed by the Kaplan-Meier plot method.
Results 149 patients underwent PTA for treatment of failing dialysis access symptoms. The most common site of stenosis in our study was the juxta-anastomotic site (49 %). The overall success rate was 96.6%. Balloon angioplasty was performed in all patients without stent placement. Sixteen (10.7%) complications were encountered in the study. At 1 year, the primary patency and the assisted primary patency rates was 60.5% and 80%, respectively. Age of the fistula (P=0.017), presence of multiple lesions (P=0.016), total lesion length >5cm (P=0.030), and diabetes mellitus (P=0.012) were significant independent predictors of loss of primary patency.
Conclusions Balloon angioplasty is safe and effective treatment modality for treatment of stenosis in failing hemodialysis access patients with good technical success and acceptable short-term primary patency rates. Repeated interventions are required to maintain patency.

Keywords: failing hemodialysis access, percutaneous transluminal angioplasty, stenosis


How to cite this article:
Saleh M, Ibrahim M, Ali H. Outcomes of balloon angioplasty for failing upper extremity dialysis access. Egypt J Surg 2020;39:756-63

How to cite this URL:
Saleh M, Ibrahim M, Ali H. Outcomes of balloon angioplasty for failing upper extremity dialysis access. Egypt J Surg [serial online] 2020 [cited 2020 Oct 1];39:756-63. Available from: http://www.ejs.eg.net/text.asp?2020/39/3/756/293687




  Introduction Top


The presence of functioning vascular access with an adequate flow is the mainstay for patients undergoing chronic hemodialysis (HD) [1]. Vascular surgeon and nephrologist should carefully monitor these accesses for early recognition of complications to prolong as much as possible the patency of this access fistula [2]. Failure of the access occurs mostly owing to stenosis developing in the venous component [3]. This stenosis, if inadequately and timely treated, is associated with a high rate of morbidity, mortality, and loss of the vascular access [4],[5]. Therefore, the Kidney Disease Outcomes Quality Initiative guidelines recommended early treatment of significant stenoses once detected in the arteriovenous fistula (AVFs) [6]. Both surgical correction and endovascular intervention are established techniques for treatment of HD patients with failing access. Currently, percutaneous transluminal angioplasty (PTA) has become the treatment of choice for stenosis in such patients [7],[8]. Advantages of balloon angioplasty are being less invasive, providing better preservation of the vessels, and associated with high technical success rate [9]. The aim of the study was to assess the immediate and short-term outcomes of the application balloon angioplasty for salvage of failing AVFs.


  Patients and methods Top


Patients

This prospective observational study was approved by our Institutional Review Board, and conducted between January 2017 and December 2018 in a high-volume, Tertiary Referral University Hospital. The study cohort included 149 consecutive patients with active HD who underwent endovascular interventions for treatment of failing upper extremity AVF.

Patients fulfilling at least one the following clinical and/or hemodynamic criteria of failing AVF were included [6]: first, difficulty with AVF cannulation; second, decreased thrill or bruit; third, prolonged bleeding from puncture site greater than 15 min after HD; fourth, elevated venous pressure greater than 150 mmHg; and fifth, decreased dialysis flow less than or equal to 200 ml/min.

Patients with inadequate fistula maturation, concomitant central venous stenosis, synthetic or composite grafts, thrombosed AVF, and known allergy to contrast agents were excluded from the study.

All patients underwent duplex ultrasound (DUS) scanning, using Philips HD5 (Philips Healthcare, Eindhoven, the Netherlands) fitted with 3–12 MHz linear array transducer, to confirm the diagnosis (≥50% reduction in luminal diameter of the feeding artery or outflow vein), identify its location and extent, assess the feeding artery, and plan for the puncture site for intervention.

All eligible patients were fully informed about the nature of the study, as well as the alternative treatment modalities available, and provided informed consent once agreed to participate in the study.

Procedure

All procedures were performed in a hybrid operative room, equipped with a mobile C-arm fluoroscopy device (Philips Pulsera; Philips Healthcare), by dedicated and experienced vascular surgeons, under local anesthesia (2% lidocaine), with optional monitored conscious sedation (midazolam and fentanyl).

Overall, 5000 IU of heparin was delivered intravenously at the beginning of the procedure to guard against thrombotic events. After gaining percutaneous access to the AVF, diagnostic fistulography of the entire access circuit to the level of the right atrium was performed, through a 6-Fr, 11-cm-long introducer sheath (Prelude; Merit Medical Systems Inc., South Jordan, Utah, USA), to confirm the diagnosis and identify the location and length of stenosis.

Stenotic lesions were negotiated using angled tip 0.035′ hydrophilic guide wires (Glidewire; Terumo Medical Corp., Somerset, New Jersey, USA), or 0.018′ guide wires (V-18 Control Wire; Boston Scientific, Marlborough, Massachusetts, USA).

Then angioplasty was performed using 3-mm to 12-mm-diameter, 4-cm to 8-cm-long high-pressure balloons (Dorado; Bard Peripheral Vascular Inc., Tempe, Arizona, USA and Mustang; Boston Scientific). The size of the balloon was selected according to the reference diameter of the most proximal nonaneurysmal vein segment. The balloon inflation time was 3–5 min and in cases of rupture or elastic recoil, inflation was extended for 5–10 min.

Postangioplasty completion angiography was obtained in two views as near to orthogonal as possible to assess the technical success of the procedure and exclude possible complications. The procedure was concluded with removal of the sheath, and hemostasis was achieved with the use of a purse-string suture [10]. Patients were prescribed lifelong aspirin 75 mg/day, and HD was resumed 1 day after the procedure.

Follow up

Monitoring and surveillance was subsequently performed using clinical and HD criteria, respectively, to detect a failing/failed access. Each patient’s HD records were reviewed, and all access-related events were documented. Follow-up information for each patient was collected at 1, 3, 6, and 12 months after the treatment procedure.

Study outcome measures

Study outcome measures were defined according to the Society of Interventional Radiology reporting standards for percutaneous interventions in dialysis access, namely [11] first, technical success defined as patent access with less than 30% residual stenosis at the end of the procedure; second, primary patency defined as the interval following the first endovascular intervention until any intervention designed to maintain or to restore patency, access abandonment, or the time of measurement of patency; and third, assisted primary patency defined as the interval following the first endovascular intervention until access abandonment or the time of measurement of patency including intervening manipulations (surgical or endovascular) designed to maintain patency.

Statistical analysis

Statistical analysis was performed using SPSS 25.0 (SPSS Inc., Chicago, Illinois, USA) and MedCalc 16.8 (MedCalc Software, Ostend, Belgium). Continuous variables were expressed as mean±SD and/or median and interquartile range, and categorical variables as frequency and percentage. Patency rates were analyzed on an ‘intention-to-treat’ basis using Kaplan–Meier survival curve, reported as proportion±SE, and intergroup differences were compared using the log-rank test. Multivariate analysis using Cox proportional-hazards regression model with stepwise approach was generated to assess the influence of various demographic, access, and lesion characteristics on primary patency, with results presented as hazard ratio (HR) and 95% confidence interval (CI). A P value less than 0.05 was considered statistically significant.


  Results Top


During the study period, 149 patients, including 99 (66.4%) males, with a mean age of 46.2±10.6 years, presenting with clinical and/or hemodynamic manifestations of failing upper extremity HD access underwent endovascular balloon angioplasty for significant stenotic lesion(s) along the access circuit.

A total of 104 AVFs (69.8%) were located on the left upper limb, and 85 AVFs (57%) were brachiocephalic. The mean interval between creation of the AVFs and endovascular intervention was 15.6±9.0 months. Patient demographics and access characteristics are summarized in [Table 1].
Table 1 Patients demographics and access characteristics

Click here to view


The main indication for intervention was decreased dialysis flow rates (83/149, 55.7%), and stenotic lesions were most commonly juxta-anastomotic (73/149, 49%) ([Figure 1]). A total of 41 accesses (27.5%) had multiple stenotic lesions, including 30 AVFs with two lesions and 11 AVFs with more than two lesions. Other lesion characteristics are illustrated in [Table 2].
Figure 1 (a) Failing left brachiocephalic fistula with juxta-anastomotic stenoses; (b) balloon angioplasty of the lesion using 6×80 mm balloon; (c) final angiogram with resolution of the stenoses.

Click here to view
Table 2 Procedural details

Click here to view


Technical success was achieved in 96.6% of cases (144/149). Failures were owing to residual stenosis greater than 30% in four patients and elastic recoil in one patient. These accesses underwent patch angioplasty (three patients) or abandonment (two patients) owing to presence of extensive lesion that was deemed beyond repair.

Complications developed in 16 (10.7%) accesses. Extravasation (due to vein rupture) occurred after balloon inflation in five patients, and hemostasis was successfully achieved by balloon tamponade combined with manually applying external compression. Persistent bleeding from the puncture site occurred in two patients and was managed with prolonged compression and additional purse-string suture when appropriate. Postoperative puncture site hematoma developed in six accesses and was treated conservatively. Moreover, three AVFs developed early thrombosis within the first postoperative day and were abandoned.

All patients were followed up for a mean period of 18.5±6.2 months. During the study period, 28 accesses were abandoned owing to either thrombosis (12 patients) or infection (16 patients). Twenty three were censored owing to loss of follow-up (nine patients), death (eight patients), and renal transplant (six patients). The post-intervention primary patency rate of the target lesions was 83.2±3.1, 74.0±3.6, and 60.5±4.2% at 3, 6, and 12 months, respectively ([Figure 2]).
Figure 2 Kaplan–Meier.

Click here to view


During follow-up, 27 (18.1%) patients showed greater than 50% target lesion recurrent stenosis and subsequently underwent preemptive high-pressure balloon angioplasty (i.e. primary patency ended). Re-interventions increased significantly the post-intervention assisted primary patency to 91.3±2.3, 86.3±2.9, and 80.0±3.4% at 3, 6, and 12 months, respectively (log-rank test, P=0.0005) ([Figure 2]).

Univariate analysis for predictors of loss of primary patency is reported in [Table 3]. Multivariate analysis using Cox proportional-hazards regression model revealed that decreased access age (HR: 0.95; 95% CI: 0.90–0.99; P=0.017), presence of multiple lesions (HR: 2.74; 95% CI: 1.21–6.18; P=0.016), total lesion length greater than 5 cm (HR: 2.25; 95% CI: 1.09–4.67; P=0.030), and diabetes mellitus (HR: 2.06; 95% CI: 1.18–3.60; P=0.012) were the only significant independent predictors of loss of primary patency ([Table 3]).
Table 3 Univariate and multivariate analyses of demographics, access, and lesion characteristics for predictors of primary patency loss

Click here to view



  Discussion Top


Maintenance of an appropriate function of the vascular access is the main target in HD patients. Thrombosis is the most fearsome complication and usually occurs owing to underlying stenosis in the access circuit. Thrombosis of the AVF requires multiple surgical procedures, which may lead to loss of the vascular access and creation of a new one [12]. Therefore, many studies supported the role of endovascular therapy in the treatment of symptomatic significant stenosis to reduce AVFs thrombosis rates [13],[14].

The main indication for angioplasty in a HD patient is the presence of luminal diameter stenosis greater than 50% detected by DUS, associated with clinical and/or hemodynamic abnormalities [15]. In the present study, decreased access flow rates (55.7%) were the main presenting symptom, suggesting that a patient’s HD access was failing. This finding correlates with the results of Tan et al. [15], emphasizing the role of regular access monitoring. Routine clinical examination, DUS scanning, and dialysis flow parameters help in early detection and salvage of patients with failing dialysis access. However, other clinical trials revealed that the effect of regular surveillance program on patency is uncertain and exposes the patients to unnecessary interventions [16],[17].

Stenosis is a common problem of AVFs and represents the main cause of dysfunction and thrombosis. Endovascular therapy has the advantage of being able to treat all types of stenosis in any location. Although, stenotic lesions can occur at any location in the dialysis access circuit, there are certain sites specific for each fistula type. For the radiocephalic fistulas, it is the juxta-anastomotic segment (located within the first 2–5 cm of the outflow vein). For the brachiocephalic fistula, it is the cephalic arch region ([Figure 3]). Moreover, upper arm transposed brachiobasilic fistula is particularly vulnerable to the development of stenosis in the end of basilic vein transposition (proximal swing point) [18], owing to both anatomic location and hemodynamic factors [19].
Figure 3 (a) Failing left brachiocephalic fistula with cephalic arch stenosis; (b) balloon angioplasty of the lesion using 12×40 mm balloon; (c) final angiogram with absence of residual stenosis.

Click here to view


The most common site of stenosis, in the current study, was the juxta-anastomotic site (49%) which is consistent with other reports [20],[21]. The inflow artery was the least frequent location (6.7%), which also correlates with results of other series [22].

The optimal access site for intervention varies according to operator preference, suspected type and site of lesion, and the anatomic pattern of the fistula ([Figure 4]). Currently, there is no consensus regarding the best approach for failing AVFs. The transbrachial approach was the most commonly used (87.9%) and preferred in the current study. The puncture of the brachial artery is usually technically straightforward and allows injection of contrast medium antegradely to the blood flow to provide good description of the arterial and venous vascular tree. Moreover, traversing the fistula in the direction of the blood flow is simple. However, compression of the brachial arterial after the procedure can damage the artery causing bleeding problems and may jeopardize the function of the fistula itself [5]. Vascular access through femoral artery offers the same advantages of transbrachial puncture in easy visualization of all the inflow and outflow vessels but necessitates the use of long wires, sheaths, and balloon catheter shafts. Although transvenous access by direct cannulation of the vein is usually relatively simple because the access vein is dilated in mature fistulas, the opacification of anastomotic, juxta-anastomotic area, and adjacent portion of the feeding artery is difficult, except by causing reflux of contrast material across the anastomosis by temporarily occluding the AVF using digital compression or inflation of a blood pressure cuff. However, this prohibits good image analysis [21].
Figure 4 (a) Failing left radiocephalic fistula with juxta-anastomotic stenosis; (b) wire crossing of the lesion; (c) final angiogram after balloon angioplasty.

Click here to view


The transradial approach to PTA for dysfunctional fistulas has rarely been reported. It allows visualization of the whole arterial and venous vascular tree of the AV fistula. Moreover, hemostasis at the radial artery puncture site can be achieved easily and safely by simple compression without obstructing the inflow and outflow of the AVF. On the contrary, the radial artery is small and may not accommodate the large sheath and balloon catheters needed for angioplasty. Puncture may be difficult because of the relatively weak radial arterial pulse owing to blood shunting through the AVF [23].

In recent years, many centers have considered balloon angioplasty as the first-line treatment modality for patients with failing AVF, whereas surgical method is suggested in case of angioplasty failure [24],[25],[26]. Angioplasty provides a quick intervention with low risk of infection. Moreover, there is no need for placement of a permanent catheter, and HD is feasible during the same day after intervention.

In the current study, technical success was achieved in 144 (96.6%) patients. This is in accordance with results reported by other authors, who reported success rates of 75–100% [27],[28]. High-pressure balloons were used for angioplasty. Stents were not used in this study because the stented venous segment cannot be used for placement of dialysis needle [21]. In addition, a stent placed across the cephalic arch protruding into the axillary vein will jeopardize the future use of the basilic and axillary vein for fistula creation or for drainage of an upper arm graft. Moreover, stents placed in this location are liable for kinking, crushing, and migration on movement of the shoulder [29].

During the past years, some researchers have investigated the use of cutting balloons and drug-coated balloons for treatment of dysfunctional AVFs [30]. However, the cost remains always a concerning problem with these techniques.

Complications were reported in 16 (10.7%) patients. Rupture of the vein is the most frequent complication of angioplasty, which can be treated conservatively, or in some cases, stent or covered stent placement may be needed [31]. In the present study, vein rupture associated with extravasation occurred after balloon inflation in five patients and was managed by balloon tamponade combined with manually applying external compression. However, other investigators reported vein rupture to be potentially more harmful, requiring transfusion and stent or stent graft placement [32].

Patency of AVFs can be maintained with both open and endovascular revisions. Although the durability of PTA seems to be shorter than surgery, the patency can be improved by repeated intervention. The target of endovascular intervention has to be 50% for primary patency during the first 6-month period [33].

During the study period, Kaplan–Meier analysis yielded a primary patency rate of 74.0±3.6 and 60.5±4.2% and assisted primary patency rate of 86.3±2.9 and 80.0±3.4% at 6 and 12 months, respectively. These results are comparable to those of other several reports [21],[34],[35],[36].

According to the most recent guidelines of vascular access, the main benefit of treatment of hemodynamically significant stenoses is decreased thrombosis, avoidance of suboptimal HD, and decrease central venous catheters, and not necessarily prolonged life of the vascular access [37]. Our strategy of repeat PTAs with very restrictive use of open revision in failing AVFs resulted in an assisted primary patency rate of 80% at 12 months, which means that most of our patients had a functioning access at one year.

Various anatomic and clinical characteristics and their relation with primary patency were studied. It was found that the newer the AVF, the shorter the primary patency (P=0.017). Other series have concluded that AVFs less than 6 months old were associated with a shorter primary patency compared with fistulas more than 6 months old (P=0.007) [38],[39],[40]. On the contrary, Manninen et al. [13] did not find a significant relation between the age of fistula and the primary patency. This may be explained by that AVFs which develop stenosis early from time of creation are likely to have either preexisting diseased vein or healthy vein with accelerated neointimal hyperplasia in response to AVF itself.

Moreover, the multivariate analysis using Cox proportional-hazards regression model revealed that the presence of multiple lesions (P=0.016), total lesion length greater than 5 cm (P=0.030), and diabetes mellitus (P=0.012) were significant independent predictors of loss of primary patency. These findings were consistent with other results. One series suggested that lesions greater than 4 cm predicted primary patency loss (P=0.004) [38]. In another study [41], it is reported that only diabetes was a significant predictor of loss of patency (P=0.04). However, other studies showed no effect of presence of diabetes mellitus, lesion length, and number of stenoses on the long-term patency of AVFs [1],[21].

Limitations of this study are being a single-center, single-arm study with relatively small number of patients and short follow-up period.


  Conclusion Top


In conclusion, endovascular intervention, in the form of balloon angioplasty, is a safe and effective treatment modality for failing AVFs. Re-stenosis is common and often requires further intervention in the form of repeat angioplasty. The durability of re-PTA is satisfactory and achieves a good assisted primary patency rate at 1 year. Newer fistulas, presence of diabetes, and multiple and long lesions (>5 cm) are associated with reduced primary patency after angioplasty. Further multicenter studies, including larger number of patients, with long-term follow-up are needed to confirm these findings.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Dias BH, Olakkengil SA. Predictors of patency following fistulography and percutaneous interventions in the treatment of nonfunctioning native vascular access. Indian J Vasc Endovasc Surg 2015; 2:7–11.  Back to cited text no. 1
  [Full text]  
2.
Anvari E, McLennan G. Monitoring and surveillance of hemodialysis access. Semin Intervent Radiol 2016; 33:25–30.  Back to cited text no. 2
    
3.
Pirozzi N, Medina J, Hanoy M. Stenosis complicating vascular access for hemodialysis: indications for treatment. J Vasc Access 2014; 15:76–82.  Back to cited text no. 3
    
4.
Clark TW, Cohen RA, Kwak A, Markmann JF, Stavropoulos SW, Patel AA et al. Salvage of nonmaturing native fistulas by using angioplasty. Radiology 2007; 242:286–292.  Back to cited text no. 4
    
5.
Maga P, Krzanowski M, Kaczmarczyk P, Koscielniak J, Partyka L. Endovascular treatment of dysfunctional arteriovenous fistula in hemodialyzed patients − the results of one year follow-up. Acta Angiol 2016; 22:143–149.  Back to cited text no. 5
    
6.
Vascular Access 2006 Work Group. Clinical practice guidelines for vascular access. Am J Kidney Dis 2006; 48(Suppl 1): S176–S247.  Back to cited text no. 6
    
7.
Wongwanit C, Simasinha T, Mutirangura P, Raungsetakit C, Chinsakchai K, Sermsathanasawadi N et al. Patency of stenotic arteriovenous fistula after percutaneous balloon angioplasty. J Med Assoc Thai 2017; 100:154.  Back to cited text no. 7
    
8.
Katsanos K, Karnabatidis D, Kitrou P, Spiliopoulos S, Christeas N, Siablis D. Paclitaxel-coated balloon angioplasty vs. plain balloon dilation for the treatment of failing dialysis access: 6-month interim results from a prospective randomized controlled trial. J Endovasc Ther 2012; 19:263–272.  Back to cited text no. 8
    
9.
Bountouris I, Kristmundsson T, Dias N, Zdanowski Z, Malina M. Is repeat PTA of a failing hemodialysis fistula durable? Int J Vasc Med 2014; 2014:369687.  Back to cited text no. 9
    
10.
Zaleski GX, Funaki B, Gentile L, Garofalo RS. Purse-string sutures and miniature tourniquet to achieve immediate hemostasis of percutaneous grafts and fistulas: a simple trick with a twist. AJR Am J Roentgenol 2000; 175:1643–1645.  Back to cited text no. 10
    
11.
Gray RJ, Sacks D, Martin LG, Trerotola SO. Reporting standards for percutaneous interventions in dialysis access. J Vasc Interv Radiol 2003; 14:S433–S442.  Back to cited text no. 11
    
12.
Scaffaro LA, Bettio JA, Cavazzola SA, Campos BT, Burmeister JE, Pereira RM et al. Maintenance of hemodialysis arteriovenous fistulas by an interventional strategy: clinical and duplex ultrasonographic surveillance followed by transluminal angioplasty. J Ultrasound Med 2009; 28:1159–1165.  Back to cited text no. 12
    
13.
Manninen HI, Kaukanen ET, Ikäheimo R, Karhapää P, Lahtinen T, Matsi P et al. Brachial arterial access: endovascular treatment of failing Brescia-Cimino hemodialysis fistulas − initial success and long-term results. Radiology 2001; 218:711-718.  Back to cited text no. 13
    
14.
Ayez N, Fioole B, Aarts RA, van den Dorpel MA, Akkersdijk GP, Dinkelman MK et al. Secondary interventions in patients with autologous arteriovenous fistulas strongly improve patency rates. J Vasc Surg 2011; 54:1095–1099.  Back to cited text no. 14
    
15.
Tan TL, May KK, Robless PA, Ho P. Outcomes of endovascular intervention for salvage of failing hemodialysis access. Ann Vasc Dis 2011; 4:87–92  Back to cited text no. 15
    
16.
Wijnen E, Planken N, Keuter X, Kooman JP, Tordoir JH, de Haan MW et al. Impact of a quality improvement programme based on vascular access flow monitoring on costs, access occlusion and access failure. Nephrol Dial Transplant 2006; 21:3514–3519.  Back to cited text no. 16
    
17.
Robbin ML, Oser RF, Lee JY, Heudebert GR, Mennemeyer ST, Allon M. Randomized comparison of ultrasound surveillance and clinical monitoring on arteriovenous graft outcomes. Kidney Int 2006; 69:730–735.  Back to cited text no. 17
    
18.
Quencer KB, Arici M. Arteriovenous fistulas and their characteristic sites of stenosis. Am J Roentgenol 2015; 205:726–734.  Back to cited text no. 18
    
19.
Lau EW, Liew R, Harris S. An unusual case of the cephalic vein with a supraclavicular course. Pacing Clin Electrophysiol 2007; 30:719–720.  Back to cited text no. 19
    
20.
Natario A, Turmel-Rodrigues L, Fodil-Cherif M, Brillet G, Girault-Lataste A, Dumont G et al. Endovascular treatment of immature, dysfunctional and thrombosed forearm autogenous ulnar-basilic and radial-basilic fistulas for haemodialysis. Nephrol Dial Transplant 2010; 25:532–538.  Back to cited text no. 20
    
21.
Rajan DK, Bunston S, Misra S, Pinto R, Lok CE. Dysfunctional autogenous hemodialysis fistulas: outcomes after angioplasty − are there clinical predictors of patency? Radiology 2004; 232:508–515.  Back to cited text no. 21
    
22.
Machado S, Ferreira A, Lucas C, Gil C, Fortes A, Neves F et al. Results of endovascular procedures performed in dysfunctional arteriovenous accesses for haemodialysis. Port J Nephrol Hypert 2012; 26:266–271.  Back to cited text no. 22
    
23.
Chen SM, Hang CL, Yip HK, Fang CY, Wu CJ, Yang CH et al. Outcomes of interventions via a transradial approach for dysfunctional Brescia-Cimino fistulas. Cardiovasc Intervent Radiol 2009; 32:952–959.  Back to cited text no. 23
    
24.
Napoli M, Prudenzano R, Russo F, Antonaci AL, Aprile M, Buongiorno E. Juxta-anastomotic stenosis of native arteriovenous fistulas: surgical treatment versus percutaneous transluminal angioplasty. J Vasc Access 2010; 11:346–351.  Back to cited text no. 24
    
25.
Long B, Brichart N, Lermusiaux P, Turmel-Rodrigues L, Artru B, Boutin JM et al. Management of perianastomotic stenosis of direct wrist autogenous radialcephalic arteriovenous accesses for dialysis. J Vasc Surg 2011; 53:108–114.  Back to cited text no. 25
    
26.
Kwon H, Choi JY, Ko HK, Kim MJ, Kim H, Park H et al. Comparison of surgical and endovascular salvage procedures for juxta-anastomotic stenosis in autogenous wrist radiocephalic arteriovenous fistula. Ann Vasc Surg 2014; 28:1840–1846.  Back to cited text no. 26
    
27.
Turmel-Rodrigues LA, Blanchard D, Pengloan J, Sapoval M, Baudin S, Testou D et al. Wallstents and Craggstents in hemodialysis grafts and fistulas: results for selective indications. J Vasc Interv Radiol 1997; 8:975–982.  Back to cited text no. 27
    
28.
Lay JP, Ashleigh RJ, Tranconi L, Ackrill P, Al-Khaffaf H. Result of angioplasty of Brescia-Cimino haemodialysis fistulae: medium-term follow-up. Clin Radiol 1998; 53:608–611.  Back to cited text no. 28
    
29.
Kian K, Asif A. Cephalic arch stenosis. Semin Dial 2008; 21:78–82.  Back to cited text no. 29
    
30.
Khawaja AZ, Cassidy DB, Al Shakarchi J, McGrogan DG, Inston NG, Jones RG. Systematic review of drug eluting balloon angioplasty for arteriovenous haemodialysis access stenosis. J Vasc Access 2016; 17:103–110.  Back to cited text no. 30
    
31.
Kornfield ZN, Kwak A, Soulen MC, Patel AA, Kobrin SM, Cohen RM et al. Incidence and management of percutaneous transluminal angioplasty-induced venous rupture in the ‘fistula first’ era. J Vasc Interv Radiol 2009; 20:744–751.  Back to cited text no. 31
    
32.
Bittl JA. Venous rupture during percutaneous treatment of hemodialysis fistulas and grafts. Catheter Cardiovasc Interv 2009; 74:1097–1101.  Back to cited text no. 32
    
33.
NKF-DOQI clinical practice guidelines for peritoneal dialysis adequacy. Am J Kidney Dis 1997; 30:S67–S136.  Back to cited text no. 33
    
34.
Miquelin DG, Reis LF, da Silva AA, de Godoy JM. Percutaneous transluminal angioplasty in the treatment of stenosis of arteriovenous fistulae for hemodialysis. Int Arch Med 2008; 1:16.  Back to cited text no. 34
    
35.
Greenberg JI, Suliman A, Angle N. Endovascular dialysis interventions in the era of DOQI. Ann Vasc Surg 2008; 22:657–662.  Back to cited text no. 35
    
36.
Flu H, Breslau PJ, Krol-van Straaten JM, Hamming JF, Lardenoye JW. The effect of implementation of an optimized care protocol on the outcome of arteriovenous hemodialysis access surgery. J Vasc Surg 2008; 48:659–668.  Back to cited text no. 36
    
37.
Schmidli J, Widmer M, Basile C, Donato G, Gallieni M, Gibbons Ch et al. Vascular Access: 2018 Clinical Practice Guidelines of the European Society for Vascular Surgery (ESVS). Eur J Vasc Endovasc Surg 2018; 55:757–818.  Back to cited text no. 37
    
38.
Maeda K, Furukawa A, Yamasaki M, Murata K. Percutaneous transluminal angioplasty for Brescia-Cimino hemodialysis fistula dysfunction: technical success rate, patency rate and factors that influence the results. Eur J Radiol 2005; 54:426–430.  Back to cited text no. 38
    
39.
Heye S, Maleux G, Vaninbroukx J, Claes K, Kuypers D, Oyen R. Factors influencing technical success and outcome of percutaneous balloon angioplasty in de novo native hemodialysis arteriovenous fistulas. Eur J Radiol 2012; 81:2298–2303.  Back to cited text no. 39
    
40.
Heerwagen ST, Hansen MA, Schroeder TV, Ladefoged SD, Lönn L. Endovascular treatment of hemodialysis arteriovenous fistulas: is immediate post-interventional blood flow a predictor of patency. J Vasc Access 2012; 13:315–320.  Back to cited text no. 40
    
41.
Wu CC, Wen SC, Yang CW, Pu SY, Tsai KC, Chen JW. Plasma ADMA predicts restenosis of arteriovenous fistula. J Am Soc Nephrol 2009; 20:213–222.  Back to cited text no. 41
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]
 
 
    Tables

  [Table 1], [Table 2], [Table 3]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Patients and methods
Results
Discussion
Conclusion
References
Article Figures