Rights and Permissions

Background Inspite of immediate technical success, neointimal hyperplasia and restenosis remain the Achilles heel of endovascular interventions. Drug-coated balloons (DCBs) have shown promising outcomes regarding anti-restenotic efficacy in management of femoro-popliteal arterial lesions compared to uncoated balloon. Objectives To evaluate the efficacy of the paclitaxel-coated balloon versus uncoated balloon angioplasty in treatment of femoropopliteal lesions regarding primary patency and restenosis at 12 months. Patients and Methods Between Sept 2017 and Sept 2019, this prospective randomized study was performed at Menoufia University hospitals. Sixty patients suffering symptomatic lower limb ischemia (Rutherford category 3 to 5) were randomly assigned into group A (30 patients) that were treated by DCB angioplasty, and group B (30 patients) that were treated by uncoated balloon (UCB) angioplasty. The primary patency, mean diameter restenosis, and binary restenosis (≥50% diameter stenosis) of the treated lesions at 12 months were collected and analyzed. Results Baseline characteristics were comparable in both groups. The 12-month mean diameter restenosis was significantly lower in DCB group than UCB group (27.8±35.2% vs. 44.9±33.8% respectively, P<0.001). Furthermore, the binary restenosis rates was significantly lower in DCB patients as compared with the UCB’s (27% vs. 46% respectively, P<0.001). The primary patency was significantly better in DCB group (70% vs. 48% respectively, P<0.001). There were no procedure-related deaths in either study group. Conclusions Treatment of symptomatic femoro-popliteal disease with paclitaxel coated balloon angioplasty is associated with superior anti-restenotic efficacy that provides a better primary patency rate compared to uncoated balloon angioplasty at 12 months.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed186    
    Printed0    
    Emailed0    
    PDF Downloaded23    
    Comments [Add]    

Recommend this journal